Technical data:
Measurement range: 100 - 1000 ppm
Measureable substances: Hydrogen (H2), diverse hydrogenous gases
Application areas: Detecting gas leaks, gas alarm, robotic, microcontroller projects
Compatible with: Raspberry Pi (with AD-converter), Arduino. etc.
Special features: High sensitivity which can be adjusted by potentiometer, detection of a wide range of concentrations
Analog Output: Values are processed by the microcontroller
Digital Output: thresholds can be set
Pins: VCC: Voltage supply 5V, GND: Ground, AOUT: Analog Output, DOUT: Digital Output
Loop voltage: ≥ 24 V DC
Heating voltage: 5.0 V ± 0.1 V
Heating resistance: 29 Ω ± 3 Ω at room temperature
Heating power: ≤ 900 mW
Sensitivity: Rs (in air)/ Rs (1000ppm H2) ≥5
Operating temperature: -10 - 50 °C