Warehouse in Europe
94%+ positive feedback
30 day money back guarantee
Specifications
Supplier product description
It is suitable for indoor usage.
The sensor can output exact values only after warmup phase.
Caution: sensor gets hot while usage!
Technical data:
Measurement range: 50 - 10000 ppm
Measureable substances: Liquefied petrol gas (LPG), propane, methane, butane and other natural gases
Application areas: Detecting gas leaks, gas alarm, robotic, microcontroller projects
Compatible with: Raspberry Pi (with AD-converter), Arduino. etc.
Special features: High sensitivity, quick reaction time, insensible for alchohol and smoke
Analog Output: Values are processed by the microcontroller
Digital Output: thresholds can be set
Pins: VCC: Voltage supply 5V, GND: Ground, AOUT: Analog Output, DOUT: Digital Output
Response time: ≤ 10 s
Recovery time: ≤ 30 s
Heating current: ≥ 24 V DC
Load resistance: 2 KΩ
Resistance in clean air: ≤ 4000 kΩ
Sensitivity: ≥ 4 (in 1000ppm butan C4H10)